O2S-FR-T5 Oxygen Sensors - Flange Mounted

  • Brand Name:SST
  • Place of Origin:United Kingdom
  • Minimum order:1
FEATURES
• Oxygen pressure range 2 mbar - 3bar
• Zirconium dioxide (ZrO2 ) sensing elements
• Non-consumption technology
• Integral heating element
• No need for temperature stabilisation
• No reference gas required
• High accuracy
• Linear output signal
• Operates with external interface boards

SPECIFICATIONS
Heater Voltage
Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A)
Stand by 2V DC (0.85A)
Pump resistance @ 700°C < 6kΩ
Permissible gas temperature -100 to 250°C
Gas flow rate 0 to 10 m/s
Repetitive permissible acceleration 5 g
Incidental permissible acceleration 30 g

/
ELECTRICAL CONNECTION
1: Pump (Red)
2: Common (Black)
3: Heater (Yellow)
4: Sense (Blue)
5: Heater (Yellow)

PERFORMANCE CHARACTERISTIC
Characteristics Min. Typ. Max. Unit
Oxygen pressure range 2 3000 mbar
Accuracy 5 mbar
Internal operating temperature 700 (4.35V DC ) °C
Response time (10-90% step) 4 s
Warm up time (prior to sensor 100 s
Warm up time (from stand by) 20 s
Output stabilisation time ~180 s

Week Technology LTD