Manufacturer of ultra pure water system

  • Place of Origin:China(Mainland)
  • Model:Center 90FV
  • Brand:Hitech
  • Flow rate of RO water:≥1.5L/min
  • Feed water:tap water
  • Flow rate of UP water:90L/hr
  • Resistivity:18.2 MΩ/cm@25C'
  • TOC:<3ppb
  • Endotoxin:<0.001EU/ml
  • Granular:<1/ml
  • Microbe:<1cfu/ml
  • Environmental temperature:5℃-35℃
  • Power:220V,50-60Hz

Application
HPLC,IC,ICP-MS,CF-AAS
Physics, electrochemical and interface research
Molecular biology and life science
Animal cells and plant cells culture

Flow Schematic

/flow schematic center 90FV.jpg

Specifications

Model Standard Eliminating endotoxin Low TOC Synthesizing
Center 60/90/120 Center 60/90/120F Center 60/90/120V Center60/90/120FV
Output(25°C) 60/90/120 L/hr 60/90/120 L/hr 60/90/120 L/hr 60/90/120 L/hr
Conductivity of RO water < Conductivity of tap water×5%
Resistivity of ultrapure water(25°C) 18.2MΩ.cm 18.2MΩ.cm 18.2MΩ.cm 18.2MΩ.cm
TOC* 10ppb 10ppb 3ppb 3ppb
Endotoxin - <0.001EU/ml - <0.001EU/ml
Bacteria <1CFU/ml <1CFU/ml <1CFU/ml <1CFU/ml
Particle (>0.2μm) <1/ml <1/ml <1/ml <1/ml
Heavy metal ion <0.1ppb <0.1ppb <0.1ppb <0.1ppb
Feed water requirements tap water,temperature:5-45°C,pressure:1.0-4.0Kgf/cm2
Dimension and weight Length 570mm,Width 600mm,Height 1500mm/Weight: about 60Kg
Electric requirements AC110-220V,50/60Hz
Power 60 series-120W, 90/120 series-240W

Features
*The system requires no special installation, connect the system to your tap water supply, plug in the system and install
the pack-it's ready to used
*Easy to maintain and operate
-A unique and easy-to-install prefiltration pack unit
-Self-maintenance of the reverse osmosis membrane
*Save space, the tank is built-in the system
*The system recirculates water when the system is not in use in order to maintain water quality
*The graphic display clearly indicates all system parameters. From water quality to knowing when it is time to change
the purification pack, you'll see at a glance what is need
*For ease-of use,the main purification technologies are contained in an innovative all-in-one pack that mean you can
change it in just a couple of minutes
*Data storage and RS 232/USB communication port
*Built-in 185 and 254 nm UV lamp for production of low TOC water required by organic-seneitive applications
*A range of filters and cartridges are available for the system to match your water requirements of bacteria-free,pyrogen-free or nuclease-free

Packaging & Shipping

We could send out your order within 7 working days after receipt of your payment .

/Package.jpg

Our Services

After-sales service

· The products customers buy from our company enjoy repair service since the day of purchase. In on year from the purchasing day, our company is obliged to replace components free of charge due to non-human-behavior factors except:

(1). Damage caused by maloperation or use in abnormal situations.

(2). Disassembly any part of the machine or human-behavior damage.

(3). Not repaired by our serviceman.

As a rich experience of pure water system manufacturer, Hitech uphold the common development concept with customers, and provide professional pre-sales support and after-sales service. We promise:

  • 12months for maintenance(except consumables).
  • On site installation supervision.
  • Free system update service.
  • Periodically return service.
  • Service hotline-400.

Main Market

Asia, The Middle East, Eastern Europe and South Africa

Company Information

Hitech Instruments has gotten the ISO9001:2008 international quality management system certificate and CE quality certificate. And will constantly bring in new technology, and devote ourselves to the development of new products in order to cover diversified demands from clients. We will provide comprehensive solutions for the lab pure water with professional pre-sales support and impeccable after-sales service. We aim to integrate products with the world market, establish first-class brand by excellent quality and gain market shares by top brand.


FAQ

Lab Water Grades

Norms define different laboratory water grades for both technical and economical reasons. The purpose of these norms is to ensure that the right water quality is used for a specific application, while limiting laboratory operating costs - Type 1 water is more expensive to produce than Type 2 or Type 3 water.


Type 3 Type 3 water is the lowest laboratory water grade, recommended for glassware rinsing, heating baths and filling autoclaves, or to feed Type 1 lab water systems.
Type 2 Type 2 water is the grade used in general laboratory applications such as buffers, pH solutions and microbiological culture media preparation; as feed to Type 1 water systems, clinical analyzers, cell culture incubators and weatherometers; and for preparation of reagents for chemical analysis or synthesis.
Type 1 Type 1 water is the grade required for critical laboratory applications such as HPLC mobile phase preparation, blanks and sample dilution in GC, HPLC, AA, ICP-MS and other advanced analytical techniques; preparation of buffers and culture media for mammalian cell culture and IVF; production of reagents for molecular biology applications (DNA sequencing, PCR); and preparation of solutions for electrophoresis and blotting.

Certificates

/certificates.jpg

Office Area

/office.jpg

Production workshop

/Prodcution workshop.jpg

Hitech Instruments Co.,Ltd

Shanghai,China Tel: 86-21-66081800 Fax: 86-21-57795003 Mobile: 18201914664 Country: China (Mainland)