DC Voltage Transducer

  • FOB Price : USD $45.00 / Piece
  • Minimum order:1
  • Place of Origin:China (Mainland)
Using linear photoelectric isolation measuring principle.
Terminal connecting input.
High accuracy with low temperature drift.
Linear measuring range: 0 ~ 120% of nominal input.
Input impedance: When VX≤ 1V, Ri≥ 50kΩ;
When VX≥ 1V, Ri≥ Vx× 10kΩ/V
Isolation: >1 KV DC/ min
Overload: 200% of nominal input, 1 minute.
Mean Time Between Failure(MTBF): >30000 hours
Various of power supply and output mode
Model Accuracy Input Output
Unit
Output Responding
Time
Static Power Consumption Power Supply Working Temperature
(º C)
BDYG-Z2D21-XXV/ 0.5 Terminal block input:
1V - 500V
VZ 5V 100ms 600mW 24V DC -10 - 70
BDYG-Z2D25-XXV/ 0.5 VZ 5V 100ms 500mW 12V DC -10 - 70
BDYG-Z4D21-XXV/ 0.5 IZ 20 mA 300ms 600mW 24V DC -10 - 70
BDYG-Z4aD21-XXV/ 0.5 IZ 4-20 mA 300ms 600mW 24V DC -10 - 70
BDYG-Z4aD25-XXV/ 0.5 IZ 4-20 mA 300ms 500mW 12V DC -10 - 70
BDYG-Z2D23-XXV/ 0.5 VZ 5V 100ms 3W 220V AC -10 - 70
BDYG-Z4aD23-XXV/ 0.5 IZ 4-20 mA 300ms 3W 220V AC -10 - 70

SAIS CO.,LTD.

242 Beihai Street, Dadong District Tel: 86-24-88718443 Country: China (Mainland)