KYN61-40.5 Armored Central AC Metal-enclosed Switchgear

  • Minimum order:1
  • Place of Origin:China

KYN61-40.5 Armored Central AC Metal-enclosed Switchgear



■Overview
KYN61-40.5(Z) type armored removable AC metal-enclosed switchgear (hereinafter referred to as switchgear) is an indoor power distribution unit with three-phase AC flow of 50 Hz and rated voltage of 40.5kV. As power plants, substations, industrial and mining enterprises to accept and distribute electrical energy, to control, protect and detect the circuit,Can also be used in places with frequent operations 。 The switchgear complies with GB/T11022-1999, GB3906--2006 and DL_404-1997.

/



■Main features
The structure of the cabinet is assembled, the circuit breaker adopts the floor-standing structure of the handcart; the new type of composite insulated vacuum circuit breaker is used, and the interchangeability is easy to replace; the screw nut propulsion mechanism is installed in the trolley frame. It can easily move the handcart and prevent misoperation and damage the propulsion structure. All operations can be carried out under the closed state of the door; the interlock between the main switch, the handcart and the switchgear door is forced by mechanical locking. \"Five-proof\" function; cable room is abundant, can connect multiple cables; fast grounding switch is used for grounding and circuit short-circuit; enclosure protection grade IP3X, handcart door open state, protection grade IP2X; product conforms to GB3906--2006 DL .404-1 997 and reference adopt the international IEC-298 standard.
■Using environmental conditions

Ambient temperature: upper limit +40 ° C, and the average value measured within 24 h does not exceed 35 ° C, the lower limit -10 ° C.

Altitude: The altitude does not exceed 1000m.

Relative humidity: The daily average does not exceed 95%, and the monthly average does not exceed 90%.

Earthquake intensity: no more than 8 degrees.

Water vapor pressure: The daily average does not exceed 2.2 kPa, and the monthly average does not exceed 1.8 kPa.

Surroundings: Locations where there is no fire, explosion hazard, severe contamination, chemical corrosion and severe vibration.

The main technical parameters

Main technical parameters of vacuum switchgear

/



Main technical parameters of vacuum circuit breaker

/


/

Urumqi Nantianya Electrical Complete-sets Equipment Co.,Ltd.

Tel: 86-991-4658766 Country: China (Mainland)