PVC Sheathed Flexible Control Cable Braiding Screened Cable/cabel

  • Minimum order:500
  • Place of Origin:China

PVC Sheathed Flexible Control Cable Braiding Screened Cable/cabel

Specifications

Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable
GB9330-1988,IEC,DIN,BS,450/750V AC

Control Cable 450/750V Copper Coductor PVC Insulated and sheathed Flexible Control Cable

Detailed Product Description

1.Standard

The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.

2.Scope of Application

The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

3.PVC sheath control cable

1)Max. Rated Temperature Of The Conductor Is 90oc

2)Max. Short-Circuit Temperature Of The Conductor Shall Not Exceed 250oc

3)Max. Sustaining Period Not Ecxeed 5 Seconds.

4)Installation Temperature Of Cable Shall Not Below 0oc .

5)Recommended Permissible Bending Radius:

A)For Non-Armormed Cable,Shall Not Be Less Than 6 Times Of The Cable's Overall Diameter.

B)For Armored Or Copper Tape Shielded Cable,Shall Not Be Less Than 12 Times Of The Cable's Overall Diameter.

C)For Soft Cable With Shield Layer,Shall Not Be Less Than 6 Times Of The Cable's Overall Diameter.

6)Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.

4.Character and Relevant Parameters for PVC control cable

1. Long-term service temperature of the cable conductor: 70 0C
2. Rated voltage: 450/750V
3. Cable lying temperature ≥ 0 0C
4. Cores: 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
5. Minimun bending radius:
Non armored ≥ Out diameter of cable 6 times
Armored layer or copper tape shielded ≥ Outer diameter of cable 12 times
Shielded layer soft cable ≥ Outer diameter of cable 6 times
PVC Insulated Control Cable Parameter (Example)

5. PVC Sheathed Flexible Control Cable Braiding Screened Cable/cabel

Type& Specification

6.Service Conditions

(1) The long-time working temperature of conductor of PVC insulated cable is 70oC

The long-time working temperature of conductor of XLPE insulated cable is 90oC

(2) The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D

河北亿腾电缆技术科技有限公司

Area 1, Donghai Building, No. 228 Jianshe North Street, Chang an District, Tel: 86-0311-88837555 Fax: 86-0311-68022931 Mobile: 15511859999 Country: China (Mainland)