The fire panel is protected by a lockable front plate that allows only authorised personal access |
1.The a microprocessor system suited for small to medium applications
2.It has eight zones that each supports up to 21 detectors
3.Each detector in turn has an alarm-repeat output for selective management in the event of a fire
4.Two supervised, silenceable alarm outputs for self-powered sirens, piezoelectric sirens, fire bells flashers and telephone diallers.
6.The gas zone is compatible with 4-20 mA gas detectors
7.Event log that can be viewed - for up to a total of 50 events - via a personal computer.
8.The fire panel is protected by a lockable front plate that allows only authorised personal access
The figure below shows the conventional fire alarm system panel. This conventional fire alarm system panels are used in a small applications , which has a small area to cover. For using conventional fire alarm system effectively a note can be stocked near the panel as to which zone corresponds to the room.
The fire panel is protected by a lockable front plate that allows only authorised personal access
Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to ...
Instruction manaul of S-6001addressable smoke detector 1.Automatic compensation function. It can be automatically compensated to improve the reliability of the smoke detector, such as external environment (temperature, humidity, dust, static, etc.) factors caused by changes ...
Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software. Key Specifications/Special Features They work perfectly with all conventional intelligent fire control panels Dual LEDs for 360-degree visibility Advanced MCU Expert Algorithm Software. Easy ...
Manual Call Point, Designed for Fire Alarm Systems and Security Alarm system. Key Specifications/Special Features Available for flush or surface mounting Plastic film on glass Test key inserted from side Open circuit with series resistor Suitable for the majority of ...
2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.Key Specifications/Special Features Four Style B (Class B) ...
Conventional Fire Alarm Control Panel with four Zones Key Specifications/Special Features Four Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in, Style Y (Class B) Notification ...
FW6000 Fire Alarm Control Panel FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed by our company for applications in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high ...
External (key-switch operated): Reset/resound/test zone lamps evacuate Silence alarm sounders Silence fault sounders Internal: One man detector test Zone isolate Revert to short-circuit: fire (no resistors in call points) External indicators: Sounder fault Battery/power supply ...
AW-AFP2189 Addressable Fire Alarm Control Panel Product Overview: AW-AFP2189 fire alarm control panel (hereinafter referred to fire control unit) is a new generation of fire alarm control panel launched. In order to meet the engineering design demand, the control unit is ...
12-32 zone fire alarm control panel for fire fighting Description AW-CFP2166-12-32 is a typical one zone fire alarm control panel which is designed based on EN54 part 2 and 4 standard. It is the heart of the fire automatic alarm system, which can realize centralized control, ...