How to adjust impeller clearance for AH type slurry

  • Minimum order:1
  • Place of Origin:China (Mainland)

The impeller clearance of the AH type slurry pump is adjusted when it leaves the factory. Therefore, there is generally no need to adjust the impeller clearance when the new machine arrives at the site. So when does it need to be adjusted? Shijiazhuang slurry pump manufacturer will take you to find out.

1. The slurry pump has been disassembled during maintenance. At this time, the impeller clearance adjusted at the factory may be damaged, and the impeller clearance needs to be readjusted.

2. The impeller has been replaced. When replacing a new impeller, we need to pay attention to whether the impeller clearance is appropriate. If it is not suitable, the impeller clearance needs to be adjusted.

3. There is abnormal noise. When the slurry pump is running, if you hear abnormal noise in the pump chamber, you need to check whether the impeller clearance is appropriate.

4. Friction. When there is friction between the impeller and the guard plate, it means that the impeller clearance is gone and needs to be adjusted.

5. The pump does not move when the hand is turned. If our slurry pump does not move when the hand pump is turned on, it may be that there is no gap between the impeller and the guard plate and they are stuck together, and the impeller gap needs to be adjusted.

If you want to know more about slurry pumps, please feel free to call us!